Solar, battery storage, EV charging: where a copper-aluminium transition belongs
Aluminium cable on a copper terminal, an aluminium cell pole under a copper lug, an aluminium mounting rail on a copper earth conductor. Where a bimetal transition is needed, and where an aluminium or nickel-plated busbar is the better answer.
In short
In solar and battery systems aluminium meets copper in three places: aluminium cable on a copper terminal, an aluminium rail on a copper earth conductor, and an aluminium cell pole under a copper lug. At a cable end use a bimetal lug or CUPAL® washer. Between cells, aluminium pole to aluminium pole, use an aluminium or nickel-plated busbar instead.
- M6–M20
- CUPAL washers, 11 sizes from stock
- 10–625mm²
- Bimetal cable lugs
- 5–10working days
- Production of parts cut to drawing
- 24h
- Quote
Where copper meets aluminium in a PV or BESS installation
Larger DC and AC cables are now often aluminium, because it is cheaper and lighter. Terminals, disconnectors, fuse bases and busbars are still mostly copper or tinned copper. Some battery cells have aluminium poles, while the main cable lug of the pack is copper. PV mounting structures are aluminium; the earth conductor is copper.
The same two processes threaten every one of these points. An insulating oxide film grows on the aluminium, and wherever moisture is present aluminium and copper form a galvanic cell. The joint warms up and the bolt loses preload over the thermal cycles. In an outdoor combiner box or an unheated container, moisture is not the exception; it is normal operation.
Not every Al/Cu point needs a bimetal part, though, and CUPAL is not always the best answer. The table below goes through the points one by one.
Which fix for which joint
Find your joint in the first column. Where CUPAL is not the right answer, we say so.
| Joint | Recommended fix | Note |
|---|---|---|
| Aluminium DC or AC cable → copper terminal (inverter, combiner, disconnector) | Bimetal cable lug; on an existing aluminium lug, a CUPAL washer | On a new termination the bimetal lug has one contact face fewer |
| Aluminium PV mounting rail → copper earth conductor, bolted | CUPAL washer under the lug | The module maker's installation manual sets the frame earthing point |
| Battery pack main pole (aluminium) → copper cable lug towards BMS, fuse or shunt | CUPAL washer, or a bimetal tab cut to drawing | The permitted pole torque is in the cell datasheet; we confirm a tab against your drawing |
| Cell → cell, aluminium pole → aluminium pole | Aluminium or nickel-plated busbar, no bimetal | No Al/Cu interface; an extra layer only adds resistance |
| Copper rack busbar → aluminium feeder cable | Bimetal cable lug or CUPAL washer | The same joint as in a switchgear cabinet |
| Aluminium feeder in a charger cabinet → copper breaker or busbar | Bimetal cable lug or CUPAL washer | The same joint as in a switchgear cabinet |
What a CUPAL transition does, and what it doesn't
CUPAL is roll-bonded copper-aluminium bimetal. In the joint its aluminium face lies against the aluminium part and its copper face against the copper, so no bare Al/Cu face remains under the bolt. At a cable end, a bimetal cable lug does the same job inside the lug body; the bimetal lug or CUPAL washer page explains when each is the better choice.
What CUPAL does not fix: a tightening torque that is too low, a badly crimped lug, or an extra layer added to a joint that is already like-for-like. On a cut CUPAL part the Al/Cu bond line is exposed at the edge; in an outdoor or humid joint the edge has to be covered.
Washers ship from stock, M6 to M20, 1–2 mm thick depending on size. Parts cut to drawing, such as a tab to fit a battery pole, we supply through custom cutting: a partner workshop cuts or punches them, by laser cutting or punching depending on quantity. Minimum one 500 × 500 mm sheet, quote within 24 hours, production 5–10 working days, EU door to door 2–4 weeks. Certificate: EN 10204 2.2 test report, 3.1 inspection certificate on request.
Battery storage (BESS): aluminium pole, copper lug and busbar
Many prismatic LiFePO4 cells have aluminium poles with a threaded hole. Several threads on the German akkudoktor.net forum deal with this: one about EVE 105 Ah cells with M4-threaded aluminium poles, another about EVE cells with aluminium screw terminals. The question is the same in both: what happens when a copper busbar or copper lug goes on them?
Between cells you do not need a bimetal. If the busbar joins two aluminium poles, there is no Al/Cu interface. The busbars supplied with cells are often nickel-plated precisely to keep copper away from aluminium; aluminium flat braid also comes up in the forum. An extra washer here solves nothing and adds one more contact face.
The forum raises the same objection. In one akkudoktor.net thread ("Kupferschiene Kontakt / Korrosion?") someone suggested Cupal washers between copper and aluminium, and the next reply said he would not do it because it increases resistance, recommending an Al/Cu contact paste instead. The objection is fair wherever the washer is an extra layer between a small pole and a busbar: every contact face is a resistance, and on a small threaded pole you cannot compensate with a high torque. A cable-lug maker's measurement points the same way; we discuss it on the cable-lug page.
Where CUPAL makes sense in a storage system
| Joint | Fix |
|---|---|
| Aluminium main pole of the pack → copper cable lug (towards BMS, fuse, shunt), in a place where moisture can reach it | CUPAL washer under the lug, with an outer diameter that covers the lug palm |
| The same, if you would rather design your own connection tab for the pole | Bimetal tab cut to drawing: aluminium face on the pole, copper face towards the lug. Send the drawing and we confirm feasibility and thickness against it |
| Copper rack busbar → aluminium feeder cable | Bimetal cable lug or CUPAL washer |
| Cell → cell | Aluminium or nickel-plated busbar, no CUPAL |
| Factory laser- or ultrasonic-welded module | Not our product; the module maker is responsible for it |
The cell datasheet gives the pole torque; do not exceed it. If the storage system stands in a dry, heated room, the risk of galvanic corrosion is low; in a garage, an unheated container or an outdoor enclosure it is higher.
Four fixes for the same pole
A qualitative comparison, without measured values. The cell and busbar makers' instructions take precedence everywhere.
| Fix | What it does | When it fits |
|---|---|---|
| Al/Cu contact paste | Keeps moisture out and slows oxidation; the dissimilar pair stays | Dry indoor storage, an accessible and inspected joint |
| Nickel- or tin-plated copper busbar | The plating separates copper from aluminium | Cell-to-cell links, with the plating intact |
| Bimetal cable lug | The transition sits in the lug body; like metal on the pole or bar | Aluminium cable onto a copper bar or terminal |
| CUPAL washer or bimetal tab cut to drawing | Aluminium face to aluminium, copper face to copper | Aluminium pole under a copper lug, where moisture can reach the joint |
EV charging infrastructure: aluminium feeder in the charger cabinet
In the distribution board of a charging site you meet the same joint as in any switchgear cabinet: the aluminium feeder lands on a copper breaker or copper busbar. A free cable end takes a bimetal cable lug; an existing aluminium lug takes a CUPAL washer under the bolt. The switchgear page gives the washer size by bolt and lug cross-section. The internal connections of the chargers themselves are designed and tested by their manufacturers; we do not supply parts for them.
If your joint is not in the table, describe it in an enquiry: what meets what, the bolt size and cross-section, and how many you need.
Questions from installers and battery builders
Applicable standards for this field
Knowledge base: CUPAL technical articles
9/8/2026
Connecting copper to aluminium: which part for which joint
Bimetal lug, Al/Cu splice, bimetallic washer or cut plate: which copper-to-aluminium connector fits each of five joints, in what size, with SKUs.
Read the full article →10/26/2026
Laser cutting or punching? Custom CUPAL parts from a drawing: which process pays off when
A custom copper-aluminium part can be cut from CUPAL sheet in three ways: on a shear, by laser or with a punching tool. What decides between them, what is different with a bimetal, and what to put in your quote request to get an accurate price first time.
Read the full article →3/1/2026
Can copper and aluminium touch? Galvanic corrosion
They can touch, but where moisture reaches the joint the aluminium corrodes: 0.55 V apart in practice. What fails, and the bimetal washer that stops it.