Solar PV · BESS · EV charging

Solar, battery storage, EV charging: where a copper-aluminium transition belongs

Aluminium cable on a copper terminal, an aluminium cell pole under a copper lug, an aluminium mounting rail on a copper earth conductor. Where a bimetal transition is needed, and where an aluminium or nickel-plated busbar is the better answer.

In short

In solar and battery systems aluminium meets copper in three places: aluminium cable on a copper terminal, an aluminium rail on a copper earth conductor, and an aluminium cell pole under a copper lug. At a cable end use a bimetal lug or CUPAL® washer. Between cells, aluminium pole to aluminium pole, use an aluminium or nickel-plated busbar instead.

M6–M20
CUPAL washers, 11 sizes from stock
10–625mm²
Bimetal cable lugs
5–10working days
Production of parts cut to drawing
24h
Quote

Where copper meets aluminium in a PV or BESS installation

Larger DC and AC cables are now often aluminium, because it is cheaper and lighter. Terminals, disconnectors, fuse bases and busbars are still mostly copper or tinned copper. Some battery cells have aluminium poles, while the main cable lug of the pack is copper. PV mounting structures are aluminium; the earth conductor is copper.

The same two processes threaten every one of these points. An insulating oxide film grows on the aluminium, and wherever moisture is present aluminium and copper form a galvanic cell. The joint warms up and the bolt loses preload over the thermal cycles. In an outdoor combiner box or an unheated container, moisture is not the exception; it is normal operation.

Not every Al/Cu point needs a bimetal part, though, and CUPAL is not always the best answer. The table below goes through the points one by one.

Which fix for which joint

Find your joint in the first column. Where CUPAL is not the right answer, we say so.

JointAluminium DC or AC cable → copper terminal (inverter, combiner, disconnector)
Recommended fixBimetal cable lug; on an existing aluminium lug, a CUPAL washer
NoteOn a new termination the bimetal lug has one contact face fewer
JointAluminium PV mounting rail → copper earth conductor, bolted
Recommended fixCUPAL washer under the lug
NoteThe module maker's installation manual sets the frame earthing point
JointBattery pack main pole (aluminium) → copper cable lug towards BMS, fuse or shunt
Recommended fixCUPAL washer, or a bimetal tab cut to drawing
NoteThe permitted pole torque is in the cell datasheet; we confirm a tab against your drawing
JointCell → cell, aluminium pole → aluminium pole
Recommended fixAluminium or nickel-plated busbar, no bimetal
NoteNo Al/Cu interface; an extra layer only adds resistance
JointCopper rack busbar → aluminium feeder cable
Recommended fixBimetal cable lug or CUPAL washer
NoteThe same joint as in a switchgear cabinet
JointAluminium feeder in a charger cabinet → copper breaker or busbar
Recommended fixBimetal cable lug or CUPAL washer
NoteThe same joint as in a switchgear cabinet

What a CUPAL transition does, and what it doesn't

CUPAL is roll-bonded copper-aluminium bimetal. In the joint its aluminium face lies against the aluminium part and its copper face against the copper, so no bare Al/Cu face remains under the bolt. At a cable end, a bimetal cable lug does the same job inside the lug body; the bimetal lug or CUPAL washer page explains when each is the better choice.

What CUPAL does not fix: a tightening torque that is too low, a badly crimped lug, or an extra layer added to a joint that is already like-for-like. On a cut CUPAL part the Al/Cu bond line is exposed at the edge; in an outdoor or humid joint the edge has to be covered.

Washers ship from stock, M6 to M20, 1–2 mm thick depending on size. Parts cut to drawing, such as a tab to fit a battery pole, we supply through custom cutting: a partner workshop cuts or punches them, by laser cutting or punching depending on quantity. Minimum one 500 × 500 mm sheet, quote within 24 hours, production 5–10 working days, EU door to door 2–4 weeks. Certificate: EN 10204 2.2 test report, 3.1 inspection certificate on request.

Battery storage (BESS): aluminium pole, copper lug and busbar

Many prismatic LiFePO4 cells have aluminium poles with a threaded hole. Several threads on the German akkudoktor.net forum deal with this: one about EVE 105 Ah cells with M4-threaded aluminium poles, another about EVE cells with aluminium screw terminals. The question is the same in both: what happens when a copper busbar or copper lug goes on them?

Between cells you do not need a bimetal. If the busbar joins two aluminium poles, there is no Al/Cu interface. The busbars supplied with cells are often nickel-plated precisely to keep copper away from aluminium; aluminium flat braid also comes up in the forum. An extra washer here solves nothing and adds one more contact face.

The forum raises the same objection. In one akkudoktor.net thread ("Kupferschiene Kontakt / Korrosion?") someone suggested Cupal washers between copper and aluminium, and the next reply said he would not do it because it increases resistance, recommending an Al/Cu contact paste instead. The objection is fair wherever the washer is an extra layer between a small pole and a busbar: every contact face is a resistance, and on a small threaded pole you cannot compensate with a high torque. A cable-lug maker's measurement points the same way; we discuss it on the cable-lug page.

Where CUPAL makes sense in a storage system

JointFix
Aluminium main pole of the pack → copper cable lug (towards BMS, fuse, shunt), in a place where moisture can reach itCUPAL washer under the lug, with an outer diameter that covers the lug palm
The same, if you would rather design your own connection tab for the poleBimetal tab cut to drawing: aluminium face on the pole, copper face towards the lug. Send the drawing and we confirm feasibility and thickness against it
Copper rack busbar → aluminium feeder cableBimetal cable lug or CUPAL washer
Cell → cellAluminium or nickel-plated busbar, no CUPAL
Factory laser- or ultrasonic-welded moduleNot our product; the module maker is responsible for it

The cell datasheet gives the pole torque; do not exceed it. If the storage system stands in a dry, heated room, the risk of galvanic corrosion is low; in a garage, an unheated container or an outdoor enclosure it is higher.

Four fixes for the same pole

A qualitative comparison, without measured values. The cell and busbar makers' instructions take precedence everywhere.

FixAl/Cu contact paste
What it doesKeeps moisture out and slows oxidation; the dissimilar pair stays
When it fitsDry indoor storage, an accessible and inspected joint
FixNickel- or tin-plated copper busbar
What it doesThe plating separates copper from aluminium
When it fitsCell-to-cell links, with the plating intact
FixBimetal cable lug
What it doesThe transition sits in the lug body; like metal on the pole or bar
When it fitsAluminium cable onto a copper bar or terminal
FixCUPAL washer or bimetal tab cut to drawing
What it doesAluminium face to aluminium, copper face to copper
When it fitsAluminium pole under a copper lug, where moisture can reach the joint

EV charging infrastructure: aluminium feeder in the charger cabinet

In the distribution board of a charging site you meet the same joint as in any switchgear cabinet: the aluminium feeder lands on a copper breaker or copper busbar. A free cable end takes a bimetal cable lug; an existing aluminium lug takes a CUPAL washer under the bolt. The switchgear page gives the washer size by bolt and lug cross-section. The internal connections of the chargers themselves are designed and tested by their manufacturers; we do not supply parts for them.

If your joint is not in the table, describe it in an enquiry: what meets what, the bolt size and cross-section, and how many you need.

Questions from installers and battery builders

Between cells, usually not. If the busbar joins two aluminium poles, an aluminium or nickel-plated busbar is the better fix, and an extra washer only adds a contact face. A CUPAL washer makes sense where a copper cable lug goes onto the pack's aluminium main pole and moisture can reach the joint.
For cell-to-cell links it is what makers usually supply, and with intact plating it works well: the nickel separates copper from aluminium. If the plating is damaged, or the bar is drilled or cut afterwards, the copper is exposed again. Follow the busbar and cell makers' instructions.
A contact paste made for aluminium-copper joints, as recommended by the cell or busbar maker. With a CUPAL washer the transition needs no paste, because each face meets its own metal. The CUPAL installation guide asks for clean faces free of oil and general-purpose grease; if you do use a compound on them, choose one made for aluminium joints.
Yes, if the cut edge is protected. At the edge of a cut CUPAL part the Al/Cu bond line is exposed, and with moisture present the galvanic cell forms again there. In an outdoor or unheated container, cover the edge and keep the joint protected from moisture. Describe the environment in your enquiry.
Where you bolt the earth conductor's lug to the aluminium rail, a CUPAL washer goes under the lug, aluminium face to the rail. The earthing point and method for the module frame are set by the module maker's installation manual; follow it. The earthing and lightning protection of the system are designed by the system designer.
We quote within 24 hours of receiving the drawing. Production takes 5–10 working days, and EU door to door is 2–4 weeks. Washers and bimetal lugs are stock items, 2–10 working days from order to delivery. Custom cutting has a minimum of one 500 × 500 mm sheet.
Yes. An EN 10204 2.2 test report with every shipment, an EN 10204 3.1 inspection certificate on request. The base material comes from the supplier, c:met GmbH (Wendelstein, Germany), which is certified to ISO 9001:2015.

Applicable standards for this field

IEC 60364-7-712
IEC 61439-1
EN 62305-3

Ask an engineer

Application not listed? Describe it and we will advise.