Aluminium cable on a copper terminal: bimetal lug or CUPAL washer?
A bimetal cable lug when the aluminium cable end is still free. A CUPAL washer when a lug is already fitted and the Al/Cu interface would sit under the bolt. A cut plate when the lug palm is wider than any washer.
In short
An aluminium cable lands on a copper terminal in one of three ways. Free cable end: a bimetal cable lug, aluminium barrel on the cable, copper palm on the bar. Aluminium lug already fitted, or a copper lug on an aluminium bar: a CUPAL® washer under the bolt. Palm wider than any washer: a plate cut to drawing.
- 10–625mm²
- Bimetal cable lugs, 109 part numbers
- M6–M20
- CUPAL washers, 11 sizes
- 1–2mm
- Washer thickness, by size
- 24h
- Quote for custom geometry
Aluminium cable, copper terminal: where the joint goes wrong
In a distribution board, an MCC, a substation or at an inverter the situation is the same: an aluminium cable arrives at a copper busbar, a copper breaker terminal or a copper stud, and a bolted joint at the cable end carries the current. If the aluminium touches the copper directly, two things start. An insulating oxide film grows on the aluminium, and wherever moisture is present the two metals form a galvanic cell. Meanwhile the different thermal expansion of the two metals works the joint on every load cycle, bolt preload drops, contact resistance rises and the joint runs warm.
Antioxidant compound slows this down, but the dissimilar pair stays in place and the joint needs regular checking. The lasting fix is to keep aluminium and copper from meeting under the bolt and let them meet inside a factory-bonded bimetal part instead. That part can be the cable lug itself, or a washer under the lug. The two are not equivalent, and they are not for the same job.
Which part goes into the joint?
The state of the cable end and the terminal material decide. Start from the first column.
| Situation | Part | Why | Availability |
|---|---|---|---|
| Aluminium cable, end still free, going to a copper bar or terminal | Bimetal cable lug (ICALCU), 10–625 mm², M8–M20 | The Al/Cu transition sits in the body of the lug; copper meets copper under the bolt. One contact face. | From stock, 2–10 working days |
| The cable already has an aluminium lug and must bolt to a copper bar | CUPAL washer, M6–M20, 1–2 mm | Aluminium face to the lug, copper face to the bar. The existing termination stays. | From stock, 2–10 working days |
| Copper lug on an aluminium bar or aluminium terminal | CUPAL washer, fitted the other way up | Copper face to the lug, aluminium face to the bar. Same part number. | From stock, 2–10 working days |
| Lug palm wider than any washer, or several lugs on one bar | CUPAL plate cut to drawing | Covers the whole palm, cut to the existing hole pattern. | Quote within 24 h, production 5–10 working days |
Bimetal lug or washer? How to decide
On a new termination with aluminium cable, the bimetal cable lug is the first choice. You crimp the aluminium barrel onto the cable and bolt the copper palm to the bar. The transition is made at the factory inside the lug body, so copper meets copper under the bolt and only one contact face remains in the joint. The ICALCU range runs from 10 to 625 mm² and M8 to M20, as tubular lugs, inline connectors and pin lugs, with 109 part numbers in stock.
The CUPAL washer is the right part where the lug is already decided. In a retrofit the cable carries an aluminium lug and you do not want to cut it off. A copper lug has to go on an aluminium bar or terminal. The equipment terminal will not take a bimetal lug. In these cases the washer goes between lug and bar, aluminium face towards aluminium, copper face towards copper. The table on the switchgear page gives the size by bolt and lug cross-section.
A cut plate is needed when the lug palm is wider than the largest washer (Ø46 mm), or when several lugs sit on one stretch of bar. We then supply CUPAL sheet cut to your drawing and the existing hole pattern. Square or rectangular transition plates are also on CUPAL bimetal plates.
One thing to avoid: do not crimp a copper lug onto aluminium cable. The Al/Cu contact then sits inside the crimp, and no washer can fix that. Connecting copper to aluminium covers what to do at cable joints and cable ends.
Does the washer add contact resistance?
Yes, and it is better to say so plainly. The cable-lug maker ERGOM has published a measurement on a 120 mm² aluminium conductor carrying about 302–303 A. An aluminium lug with an Al-Cu washer on a copper bar measured 13.4–18.1 µΩ transition resistance and a steady-state temperature of 46.7–50.3 °C. ERGOM's own friction-welded KMA bimetal lug measured 1.9–2.1 µΩ and 36.1–37.1 °C. Their conclusion: the washer raises the resistance of the connection, and with it the temperature rise of the lug.
It is one manufacturer's own test. It gives no sample count and no test standard, and it did not test our washer. The direction makes physical sense, though: with an aluminium lug and a washer there is one contact face between lug and washer and a second between washer and bar, while a bimetal lug has only one. Our recommendation follows from that:
| Situation | Recommended part |
|---|---|
| New termination, aluminium cable, free cable end | Bimetal cable lug |
| Existing aluminium lug on a copper bar, retrofit | CUPAL washer |
| Copper lug on an aluminium bar or terminal | CUPAL washer, the other way up |
| Wide palm, several lugs, custom hole pattern | Cut CUPAL plate |
If a washer goes into the joint, three things keep its resistance low. The outer diameter should cover the whole lug palm, not just the area round the bolt; if the palm is wider, step up to a larger outer diameter. The contact faces should be clean and free of oxide. Torque comes from the lug or equipment manufacturer. We do not publish resistance figures of our own, because we have no such measurement.
Typical Al/Cu cable-end joints
Three common points, and which part belongs in each.
Aluminium cable (overhead or underground) → copper bar in a service cabinet
The problem you need to solve. The cabinet is outdoors or semi-outdoors, so the joint can get damp. The cable is aluminium, the bar copper, and nobody opens the joint for years.
How CUPAL solves it. On a new termination, a bimetal cable lug. On an existing aluminium lug, a CUPAL washer, but only in a dry, closed cabinet; in a damp location the bond line exposed at the cut edge of the washer makes the bimetal lug the better choice. If in doubt, describe the environment to us.
LV or MV aluminium cable → copper busbar in switchgear
The problem you need to solve. A large aluminium cable lands on the copper bar of the cabinet. If the cable end is still free, this is the moment that decides which part goes into the joint.
How CUPAL solves it. A bimetal cable lug on the cable, copper palm on the bar. If the cable already carries an aluminium lug, a CUPAL washer between lug and bar, with an outer diameter that suits the lug cross-section.
PV and BESS DC cabling → copper disconnector or fuse base
The problem you need to solve. The aluminium DC cable from the inverter or the storage system lands on copper terminals. The joint sees a daily thermal cycle.
How CUPAL solves it. The same decision as above. The other Al/Cu points in solar and battery systems are covered on the renewable-energy page.
Questions from installers
Recommended CUPAL products
Applicable standards for this field
Knowledge base: CUPAL technical articles
9/8/2026
Transition washer: toothed or bimetallic? How to tell which one your drawing means
Two physically different parts are sold as a transition washer: a toothed copper-alloy washer and a roll-bonded copper-aluminium bimetal disc. How to tell them apart, which suits which joint, and the 11 bimetal sizes from M6 to M20.
Read the full article →9/8/2026
Connecting copper to aluminium: which part for which joint
Bimetal lug, Al/Cu splice, bimetallic washer or cut plate: which copper-to-aluminium connector fits each of five joints, in what size, with SKUs.
Read the full article →4/2/2026
Which CUPAL washer fits? Choosing a size from M6 to M20
The bolt sets the bore and the cable-lug palm sets the outer diameter. A selector table for CUPAL bimetallic washers M6–M20, 16–46 mm OD, 1–2 mm thick by size, plus which way round they go.
Read the full article →