Copper cable on an aluminium mast: a lasting joint without galvanic corrosion
Copper bonding, earthing or lightning cable on an aluminium mast, mast step or busbar, from AWG
In short
A copper bonding, earthing or lightning conductor bolted straight to an aluminium mast forms a galvanic cell that salt spray and condensation drive hard. The aluminium corrodes and the joint becomes an insulator while still looking sound. A CUPAL® washer or cut plate puts aluminium against the mast and copper against the lug.
- M6–M20
- Washers, 11 sizes from stock
- 0.5–2.0mm
- Plate thickness for parts cut to drawing
- 2–10working days
- Stock washers, order to delivery
- 24h
- Quote
What happens when you bolt copper cable to an aluminium mast
The mast is aluminium because it has to be light. The bonding, earthing or lightning conductor is copper because it has to conduct. Where the two meet under one bolt, a galvanic cell forms as soon as there is an electrolyte: salt spray, rain, condensation. Aluminium is the less noble metal, so the mast corrodes, not the cable. The galvanic corrosion guide explains the mechanism and the galvanic series.
What makes it dangerous rather than merely ugly is that the corrosion product, aluminium oxide, is an insulator. The joint stays mechanically tight and quietly stops conducting. On a lightning path that means the protection you believe you have is not there when it matters; on a bonding or DC negative circuit it shows up as drifting readings and intermittent faults.
Salt water speeds it up, which is why the damage shows after a single season at sea. On fresh water, on lakes and rivers, the process is slower, but the conditions are the same: the two metals touch, and rain, mist and condensation inside the boat keep the joint wet. It gets to the same place, only later.
What to put in the joint
A copper-aluminium bimetal transition: one piece of material with an aluminium face and a copper face, roll-bonded at the mill. It is not a coating and not a plating; the Cu/Al interface sits inside the part. Fitted correctly, the aluminium face goes against the mast and the copper face against the copper cable lug, so every contact is metal against its own metal and nothing drives the corrosion.
Two forms cover almost every mast joint:
- CUPAL washer for a single bolted lug, M6 to M20, 1–2 mm thick depending on size, from stock. The outer diameter should cover the whole lug palm, not just the area round the bolt.
- CUPAL plate cut to drawing where aluminium and copper meet over a larger face (a mast step plate, a chainplate landing, an aluminium busbar in the switch panel), or where the fitting has its own hole pattern. The plate is cut from 0.5–2.0 mm CUPAL sheet to your drawing; a mast step usually needs the thicker gauge, and we recommend one from the drawing.
Antioxidant paste slows the same reaction but leaves the galvanic couple in place and has to be re-applied. A stainless washer does not remove the couple either; it adds a third metal that is also cathodic to aluminium. The bimetal transition removes the cause, so the inspection becomes mainly mechanical: is the bolt still tight, is the joint still covered.
Fitting notes
- Orientation matters. Aluminium face to the mast, copper face to the cable. Fitted the wrong way round you recreate exactly the dissimilar contact you set out to remove.
- Clean both faces at assembly. Aluminium re-oxidises quickly, so clean just before you assemble. Keep oil and general-purpose grease off the contact faces; if you add a contact compound, use one made for aluminium joints. The sequence is in the CUPAL installation guide.
- Protect the cut edge. Like metals meet on the faces of a washer or plate, but at the cut edge the Al/Cu bond line is exposed. Seal or cover a joint that sees spray or condensation, and if you are unsure, describe the situation and we will answer for that joint.
- Cross-section, not just size. CUPAL conducts 41.9 m/(Ω·mm²), about 72 % of copper. On a bonding or lightning path that rarely matters, because the bolt and the fitting set the contact area; on a joint carrying working current, allow for it.
- On a boat this is one part of a system. Bonding, lightning protection and galvanic isolation are separate problems that interact. A bimetal transition fixes the dissimilar-metal joint. It is not a galvanic isolator, and it does not replace anode protection or a properly designed ground path. We supply the material and its EN 10204 certificate, not vessel or class certification.
If your joint is not on a mast but at an aluminium cable end, an in-line cable joint or a busbar transition, connecting copper to aluminium names the part for each of the four cases. The building version of the same joint, an aluminium down-conductor on a copper earth, is on the lightning protection page.
Where the joint actually sits
Four places a copper conductor meets aluminium on a boat or a mast, and what each one needs.
Bonding or lightning cable to an aluminium mast
The problem you need to solve. A copper bonding conductor, often tinned, is bolted to a lug on the mast wall or at the mast step. Spray and condensate run down the mast and sit at exactly that bolt. Within a season or two the aluminium under the lug is powdery and the path resistance has climbed.
How CUPAL solves it. A CUPAL washer under the lug, aluminium face to the mast. For a heavy conductor, such as a 4/0 AWG lug, a plate cut to drawing spreads the contact over the whole lug palm instead of concentrating it at the bolt.
Mast step to the deck or keel bonding point
The problem you need to solve. A deck-stepped or keel-stepped mast lands on a plate that is bonded back to the common point with copper. The step is the wettest place on the rig, it collects everything that runs down the spar, and the joint is usually bolted once and then left for years.
How CUPAL solves it. A CUPAL plate cut from a drawing to the step footprint. The whole bearing face becomes a bimetal transition instead of a ring of oxide forming round each bolt. Seal or cover the edge of the plate.
Copper lug onto an aluminium busbar in the panel
The problem you need to solve. Distribution and battery switch panels mix copper cable lugs with aluminium bars. The cabin is humid, and at a high-current joint rising contact resistance means heat before it means a fault.
How CUPAL solves it. A CUPAL washer between lug and bar, copper face to the lug, chosen so the outer diameter covers the whole lug palm.
Antenna, radar or signal mast ashore
The problem you need to solve. The same joint without the boat: an aluminium mast, a copper earth conductor, and a coastal or industrial atmosphere. A lightning path that measures fine on the day it is installed and drifts out of specification without anyone re-testing it.
How CUPAL solves it. CUPAL strip or a cut plate where the down-conductor meets the earth conductor, under the tested clamp.
Compared to what is usually fitted
Four ways this joint gets made, and how each one ages in damp, salty air.
| Approach | What it does to the couple | Maintenance | How it ages |
|---|---|---|---|
| Copper lug bolted straight to aluminium | Nothing; full Al/Cu couple | Regular dismantling, cleaning and re-making | Visible corrosion at sea within a season |
| Antioxidant or jointing paste | Slows the reaction; the couple remains | Regular inspection and re-application | Extends it, does not remove it |
| Stainless washer between the two | Adds a third metal, also cathodic to aluminium | Yearly dismantling and cleaning | Delays it |
| CUPAL bimetal washer or plate | Removes the couple; each metal meets its own kind | Mechanical check, plus a check that the edge is still covered | No Al/Cu couple on the faces; the cut edge needs protection |
What people ask us about this joint
Recommended CUPAL products
Applicable standards for this field
Knowledge base: CUPAL technical articles
9/8/2026
Connecting copper to aluminium: which part for which joint
Bimetal lug, Al/Cu splice, bimetallic washer or cut plate: which copper-to-aluminium connector fits each of five joints, in what size, with SKUs.
Read the full article →4/10/2026
CUPAL bimetal installation and processing guide
Fitting a CUPAL bimetal washer step by step: surface prep, which face goes where, torque and edge protection outdoors. Plus the 260 °C / 4 h processing limit.
Read the full article →3/1/2026
Can copper and aluminium touch? Galvanic corrosion
They can touch, but where moisture reaches the joint the aluminium corrodes: 0.55 V apart in practice. What fails, and the bimetal washer that stops it.
Read the full article →